Skip to content

Fluke FLK-A3000 FC KIT Wireless RMS AC Current Clamp Kit

by Fluke
SKU: FLK-A3000 FC KIT
Sold out
Original price $986.70 - Original price $986.70
Original price
$986.70
$986.70 - $986.70
Current price $986.70

Connect the a3000 FC Wireless AC Current Clamp Module to your test point, and view the results up to 20 meters away on the 3000 FC Wireless Digital Multimeter.

You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the FC Wireless AC Current Clamp Module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.

Now you can take readings on moving machinery, with only the measurement module in harm’s way.

Features:

The Fluke a3000 FC Wireless AC Current Clamp Kit provides measurement of many common electrical parameters

The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement troubleshooting:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:

  • True-RMS AC clamp meter
  • Measure up to 400 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function

Specifications:

Fluke 3000 FC Series Wireless Multimeter
  • AC Voltage
    • Range¹ / resolution
      • 600.0 mV / 0.1 mV
      • 6.000 V / 0.001 V
      • 60.00 V / 0.01 V
      • 600.0 V / 0.1 V
      • 1000 V / 1 V
    • Accuracy
      • 45 Hz to 500 Hz 1.0% + 3
      • 500 Hz to 1 kHz 2.0% + 3
  • DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    • mV
      • Range / resolution: 600.0 mV / 0.1 mV
      • Accuracy: 0.09% + 2
    • V
      • Range / resolution
        • 6.000 V / 0.001 V
        • 60.00 V / 0.01 V
        • 600.0 V / 0.1 V
        • 1000 V / 1 V
      • Accuracy
        • 0.09% + 2
        • 0.15% + 2
    • )))
      • Range / resolution: 600 Ω / 1 Ω
      • Accuracy: Meter beeps at
    • Ω
      • Range / resolution
        • 600.0 Ω / 0.1 Ω
        • 6.000 kΩ / 0.001 kΩ
        • 60.00 kΩ / 0.01 kΩ
        • 60.00 kΩ / 0.1 kΩ
        • 600.0 kΩ / 0.001 MΩ
        • 50.00 MΩ / 0.01 MΩ
      • Accuracy
        • 0.5% + 2
        • 0.5% + 1
        • 1.5% + 3
    • Diode test
      • Range / resolution: 2.000 V / 0.001 V
      • Accuracy: 1% + 2
    • µF
      • Range / resolution
        • 1000 nF / 1 nF
        • 10.00 μF / 0.01 μF
        • 100.0 μF / 0.1 μF
        • 9999 μF1 / 1 μF
      • Accuracy:
        • 1.2% + 2
        • 10% typical
  • AC and DC Current
    • mA AC (45 Hz to 1 kHz)
      • Range1 / resolution: 60.00 mA / 0.01 mA
      • 400.0 mA3/ 0.1 mA
      • Accuracy: 1.5% + 3
    • mA DC2
      • Range1 / resolution: 60.00 mA / 0.01 mA
      • 400.0 mA3/ 0.1 mA
      • Accuracy: 0.5% + 3
  • Frequency
    • Range / resolution
      • 99.99 Hz / 0.01 Hz
      • 999.9 Hz / 0.1 Hz
      • 9.999 kHz / 0.001 kHz
      • 99.99 kHz / 0.01 kHz
    • Accuracy: 1 0.1% + 1
  • mA Function
    • Overload protection: Fused, 44/100 A, 1000 V FAST Fuse
    • Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
  • MIN/MAX Recording Accuracy
    • DC functions: ±12 counts for changes > 350 mS in duration.
    • AC functions: ±40 counts for changes > 900 mS in duration.
  • Maximum voltage: between any terminal and earth ground 1000 VDC or AC rms
  • Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
  • Display (LCD):
    • Update rate 4/sec
    • Volts, amps, ohms: 6000 counts
    • Frequency: 10,000 counts
  • Capacitance: 1,000 counts
  • Battery type: Three AA Alkaline batteries, NEDA 15A IEC LR6
  • Battery life: 250 hours minimum
  • RF communications: 2.4 GHZ ISM Band
  • RF communication range: Open air, unobstructed Up to 20 m
  • Obstructed, sheetrock wall: Up to 6.5 m
  • Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5 m
  • Temperature
    • Operating: -10°C to 50°C
    • Storage: -40°C to 60°C
  • Temperature coefficient: 0.1 x (specified accuracy) / °C ( 28°C)
  • Relative humidity:
    • 0% to 90% (0°C to 35°C)
    • 0% to 75% (35°C to 40°C)
    • 0% to 45% (40°C to 50°C)
  • Altitude Operating: 2,000 m
  • Storage: 12,000 m
  • Electromagnetic compatibility:
    • EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006
    • ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    • V1.8.1:2008
    • FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    • FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
  • Safety compliance:
    • ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    • CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    • UL 61010-1: 3rd edition
    • IEC/EN 61010-1:2010
  • Certifications: CSA, FCC, CE
  • Ingress Protection (IP): rating IP54
  • Pollution Degree: 2
  • Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
  • Weight: 340 g (12 oz)
  • Warranty Three years

    * Not compatible with Fluke CNX test tools

    Fluke a3000 FC Wireless AC Current Clamp Module

    • Range: 0.5 A to 400.0 A
    • Resolution: 0.1 A
    • Accuracy: 400.0 A: 2% ±5 digits (10 Hz to 100 Hz), 2.5% ±5 digits (100 Hz to 500 Hz)
    • Inrush: Max displayed reading 999.9A
    • Crest factor (50 Hz / 60 Hz):
      • 3 at 500 A
      • 2.5 at 600 A
      • 1.42 at 1000 A
      • Add 2% for C.F. > 2
    • LCD w/backlight: 3½ digits
    • Log rate/interval: 1 sec minimum/adjustable by PC
    • Battery type: 2 AA, NEDA 15 A, IEC LR6
    • Battery life: 400 hours
    • Memory Record: up to 65,000 readings
    • RF communications: 2.4 GHZ ISM Band
    • RF communication range: Open air, unobstructed Up to 20 m
    • Obstructed, sheetrock wall: Up to 6.5 m
    • Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
    • Operating temperature: -10°C to +50°C
    • Storage temperature: -40°C to +60°C
    • Temperature coefficient: Add 0.1 x (specified accuracy) / °C ( 28°C)
    • Operating humidity:
      • 90% at 35°C
      • 75% at 40°C
      • 45% at 50°C
    • Altitude Operating: 2,000 m
    • Storage: 12,000 m
    • EMC: EN 61326-1:2006
    • Safety compliance: IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
    • Safety rating: CAT III 600 V
    • Certifications: CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    • Ingress Protection (IP) rating: IP30
    • Pollution Degree: 2
    • Jaw opening: 34 mm (1.33 in)
    • Size (H x W x D): 20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in)
    • Weight: .22 kg (8 oz)
    • Warranty: Three years

    * Not compatible with Fluke CNX test tools

    Includes:

    • Fluke 3000 FC Series Wireless Multimeter
    • Fluke a3000 FC Wireless AC Current Clamp Module
    • TL175 Test Leads
    • AC175 Alligator Clips