Skip to content

Fluke FLUKE-6500-2 AU Portable Appliance Tester

by Fluke
SKU: FLUKE-6500-2 AU
Sold out
Original price $4,228.00 - Original price $4,228.00
Original price
$4,228.00
$4,228.00 - $4,228.00
Current price $4,228.00

Features:

  • Dedicated key for each test for ‘one-touch’ testing
  • Pre-set pass/fail levels to save time
  • Large backlit display for easy reading
  • Single mains socket for appliance connection
  • Separate IEC socket for easy mains/extension lead testing
  • Detachable test leads for quick field replacement
  • Integral carrying handle
  • USB port for data transfer
  • Integral QWERTY keyboard for rapid data entry
  • Additional USB memory capability for back-up data storage and transfer to PC
  • Large backlit graphics display
  • Pre-set, auto-test sequences for user convenience
  • Integral site, location and description codes for faster data processing
  • Memory review facility for more on-site control
  • USB port for data transfer

Specifications:

  • Test specifications
    • The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH.
    • Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.
    • The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.
  • Power-on test- The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
    • Display range: 90 V to 264 V
    • Accuracy: at 50 Hz ±(2% + 3 counts)
    • Resolution: 0.1 V
    • Input impedance: > 1 MΩ // 2.2 nF
    • Maximum input mains voltage: 264 V
  • Earth bond test (Rpe)
    • Display Range: 0 to 19.99 Ω
    • Accuracy (after bond test zeroing): ±(5% + 4 counts)
    • Resolution: 0.01 Ω
    • Test current:
      • 200 mA AC -0% +40% into 1.99 Ω
      • 10 A AC ±20% into 25 mΩ at 230 V
    • Open circuit voltage: > 4 V AC, < 24 V AC
    • Bond test zeroing can subtract: up to 1.99 Ω
  • Insulation test (Riso)
    • Display range: 0 to 299 MΩ
    • Accuracy: ±(5% + 2 counts) from 0.1 to 300 MΩ
    • Resolution:
      • 0.01 MΩ (0 to 19.99 MΩ)
      • 0.1 MΩ (20 to 199.9 MΩ)
      • 1 MΩ (200 to 299 MΩ)
    • Test voltage: 500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0% +25% at 250 kΩ load
    • Test current: > 1 mA at 500 kΩ load, < 15 mA at 0 Ω
    • Auto discharge time: < 0.5 s for 1 μF
    • Max. capacitive load: Operational up to 1 μF
  • Touch current test
    • Display range: 0 to 1.99 mA AC
    • Accuracy: ±(4% + 2 counts)
    • Resolution: 0.01 mA
    • Internal resistance (via probe): 2 kΩ
    • Measuring method: Probe*
  • Substitute leakage current test
    • Display range: 0 to 19.99 mA AC
    • Accuracy: ±(2.5% + 3 counts)
    • Resolution: 0.01 mA
    • Test Voltage: 100 V AC ±20%
  • Load/leakage test: load current
    • Display range: 0 A to 13 A
    • Accuracy: ±(4% + 2 counts)
    • Resolution: 0.1 A*
  • Load/leakage test: load power
    • Display range: 230 V Mains 0.0 VA to 3.2 kVA
    • Accuracy: ±(5% + 3 counts)
    • Resolution: 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*
  • Load/leakage test: leakage current
    • Display range: 0 to 19.99 mA
    • Accuracy: ±(4% + 4 counts)
    • Resolution: 0.01 mA*
  • PELV test
    • Accuracy: at 50 Hz ±(2% + 3 counts)
    • Overload protection: 300 V rms
    • Warning threshold: 25 V rms
  • RCD test: trip current
    • Operational error: ±10%
    • Nominal: 30 mA
    • Accuracy: ±5%
  • RCD test: trip time
    • Standard requirement: 61557 Part 6; tolerance of rated test current 0% to +10%
    • Operational error: ±10%
    • RCD type: AC general-purpose 30 mA
    • Display range: 310 ms
    • Resolution: 0.1 ms
    • Accuracy: 3 ms
    • Trip time limit at 100% (30 mA): 300 ms
    • Trip time limit at 500% (150 mA): 40 ms

*The appliance under test is energized at mains potential.

  • Operating temperature: 0 to 40 °C
  • Relative humidity
    • Non condensing <10 °C
    • 95% from 10 to 30 °C
    • 75% from 30 to 40 °C
  • Safety rating
    • Complies with EN61010-1 3rd edition
    • CAT II, 300 V, pol 2
  • Size (L x W x H) 200 x 275 x 114 mm
  • Weight 3.13 kg
  • Power supply: 230 V +10% -15%, 50 Hz ±2 Hz or (6500-2 only: 110V +10% -15%,50 Hz ±2 Hz)
  • Power consumption (tester)
    • 13 W typical (idle)
    • 60 W max. during 25A Bond test
  • Storage
    • Temperature: -10 to 60 °C
    • Corrosion: 70 °C @ 95% RH for 5 days max.
  • Operating altitude: 0 up to 2000 m
  • Sealing: IP-40 (enclosure), IP-20 (connectors)
  • EMC: Complies with EN61326-1, portable
  • EMI: Immunity 3 V/m

Includes:

  • Fluke 6500-2 Portable Appliance Tester
  • User's manual on CD
  • Quick reference guide
  • Hard carrying case
  • Test lead
  • Test probe
  • Crocodile clip
  • Mains cord
  • USB stick
  • USB cable